About Us
Description
The 70KW Commercial Heat Pump Hot Water Heater is engineered to meet the high demands of large-scale hot water usage in commercial settings. This powerful and efficient system provides a sustainable solution for businesses seeking to minimize energy consumption while ensuring a reliable supply of hot water. Designed with advanced technology and robust construction, it’s ideal for hotels, hospitals, factories, and other commercial facilities that require a continuous and efficient hot water supply.
The 70KW Commercial Heat Pump Hot Water Heater operates as an advanced heat pump hot water system, leveraging ambient air to heat water. This system is highly efficient, as it extracts heat from the surrounding air and transfers it to the water, significantly reducing energy consumption compared to traditional water heating methods. This heat pump technology ensures that the system delivers hot water quickly and reliably, even in demanding environments, making it an ideal solution for commercial-grade applications.
As an air source heat pump for hot water only, this system focuses solely on heating water, ensuring maximum efficiency and performance. The air source technology allows the heat pump to operate in a wide range of temperatures, ensuring consistent hot water delivery regardless of the external environment. This specialized focus on water heating makes the 70KW unit particularly effective for businesses that require large volumes of hot water without the need for additional heating or cooling functions.
The 70KW Commercial Heat Pump is a dedicated heat pump hot water unit designed for commercial use. With its high capacity, it can meet the hot water needs of large facilities, providing a steady supply of hot water even during peak demand periods. The system is equipped with a high-efficiency compressor and advanced heat exchange technology, ensuring rapid heating and consistent performance. This makes it an excellent choice for businesses that require a reliable and energy-efficient hot water system.
This hot water system with heat pump offers a versatile and cost-effective solution for commercial buildings. By utilizing heat pump technology, the system reduces energy costs and greenhouse gas emissions, making it a more sustainable choice compared to traditional boilers. The 70KW unit is designed to integrate seamlessly with existing plumbing and heating infrastructure, making it easy to install and operate. The system's design also includes features like smart controls and monitoring capabilities, allowing for precise temperature management and operational efficiency.
The 70KW Commercial Heat Pump Hot Water Heater is built to commercial standards, ensuring durability, reliability, and long-term performance. As a commercial-grade heat pump, it is designed to handle the rigorous demands of large-scale operations, with heavy-duty components that ensure consistent performance over time. The system is also equipped with safety features and protections that prevent overheating and ensure safe operation in all conditions. This makes it an ideal choice for businesses that require a robust and dependable hot water solution.
One of the key advantages of the 70KW Commercial Heat Pump Hot Water Heater is its energy efficiency. By using a heat pump to transfer heat from the air to the water, the system can achieve high levels of efficiency, reducing energy consumption and operational costs. This not only benefits the bottom line but also reduces the environmental impact of the business. The use of eco-friendly refrigerants and advanced heat exchange technology further enhances the system's sustainability, making it a smart choice for businesses looking to reduce their carbon footprint.
The 70KW Commercial Heat Pump is designed for easy installation and minimal maintenance. Its compact and modular design allows it to be installed in a variety of locations, from mechanical rooms to outdoor areas. The system's advanced controls and diagnostics make it easy to monitor and maintain, reducing the need for frequent service calls and ensuring long-term reliability. Additionally, the system is designed for easy integration with existing hot water infrastructure, making it a convenient and cost-effective upgrade for businesses looking to improve their hot water systems.
The 70KW Commercial Heat Pump Hot Water Heater is a powerful, efficient, and environmentally friendly solution for businesses that require a reliable hot water supply. With its advanced heat pump technology, high capacity, and commercial-grade construction, it offers an excellent balance of performance, efficiency, and sustainability. Whether for hotels, hospitals, or other large facilities, this heat pump hot water system provides a dependable and cost-effective solution that meets the demands of modern commercial operations.
parameter
| KFXR-070UCII | |||
| Heating mode | Circulating | Brand | Panasonic |
| Ambient temp. range | -15℃~+43℃ | Refrigerant | R32 |
| Rated heating capacity | 70kW | Max. temp. outlet water | 60℃ |
| COP | 4.1 | Circulating waterpipe nozzle | DN100 |
| Rated power input | 17kW | Outlet nozzle | DN100 |
| Max. running current | 45A | Circulating water flow | 12.04m³/h |
| Power supply | 380v 3N~50Hz | Noise | 69dB/(A) |
| Dimension (W×D×H) | 2100*1100*2000 | Packing Dimension (W×D×H) | 2190*1190*2150 |
| N.W. | 700KG | G.W. | 720KG |
| Remarks: 1. Test conditions: (DB/WB) 20°C/15°C, inlet water temperature 15°C, outlet water temperature 55°C. 2. Due to product improvement, above datas are subject to change without prior notice, please take the rating plate as standard. 3. The heat pump system is suitable for city water that meets the national standard. If use groundwater, well water, etc., it must be treated to reach the national standard tap water quality before use. If the water quality is poor, install a filter and water processor. | |||
Details
.png)
Commercial Central Hot Water Solutions
AIROSD provides one-stop central hot water solutions for commercial offices, hotels, factories, hospitals, and schools, and the series of products can be used together to meet the central hot water needs of
different buildings.
.png)
Branded accessories Stable performance
Copeland scroll compressor, quiet and high efficiency. High efficiency heat exchanger. Schneider electrical components. Intelligent controlling system. Intelligent EE valve, excellent efficiency at different
ambient temp. Automatically defrosting. Easy installation and LCD operation.
.png)
Safe and reliable
The heat pump absorbs a lot of energy from the air, COP>4.0, energy saving 75%.Adopting the large insulated water tank for 24h hot water supplies.Central hot water system can meet the multi-point hot
water requirement at the same time.
.png)
How heat pumps work
AIROSD heat pump can work normally at -15℃, transferring the air heat source above -15℃ in the air to the air generator causing the heat generated by the refrigerant in the air exchanger to heat up and
vaporize to be released into the water, causing the water temperature to rise. Air water heater is currently one of the world's highest energy efficiency ratio of hot water equipment.
.png)
Widely choose for heating capacity
Working ambient temperature down to - 15 ° C, The unit will be not affected by wind, rain, thunder and snow weather.
.png)
Automatic defrost mode + anti-secondary long ice technology
The outdoor unit adopts outdoor temperature sensor and heat exchanger temperature sensor to perform variable-parameter defrosting and accurately grasp the defrosting timing, whicheffectively solves the problem of "no defrosting when there is frost,but defrosting without frost", and the amount of frost perunit time is significantly reduced. Only 1/3 of the normal defrost mode. At the same time.with the unigue
anti-secondary long-ice technology of AlROSD. It can ensure that there is no frost at the bottom of the outdoor heat exchanger during heating in winter, and at the same time, the ice-water mixture left along
the fins can be fully heated to a liquid state during defrosting. It is drained through the bottom drain hole to avoid poor heating effect caused by the accumulation of frost at the bottom.