About Us
Description
The 70℃ R417A 45KW EVI Heating Cooling Heat Pump is a state-of-the-art solution designed to deliver exceptional performance for both heating and cooling applications. Engineered with advanced Enhanced Vapor Injection (EVI) technology, this heat pump offers superior efficiency and flexibility, making it ideal for various commercial and residential environments.
At the core of the 70℃ R417A 45KW unit is its advanced EVI Heating Cooling Heat Pump technology. EVI technology enhances the heat pump's ability to operate efficiently even in extreme temperatures, allowing it to provide consistent heating and cooling performance. This makes it an ideal choice for environments that experience significant temperature fluctuations or require robust climate control solutions.
Designed as a heat pump for ducted system, this unit integrates seamlessly with existing ductwork to provide comprehensive climate control throughout a building. Its compatibility with ducted systems ensures even distribution of heated or cooled air, maintaining consistent indoor temperatures across large spaces. This feature is particularly beneficial for commercial properties and large residential homes where uniform climate control is essential.
The 70℃ R417A 45KW model functions effectively as a heat pump system air conditioning unit. It excels in cooling applications, providing efficient and reliable air conditioning for both commercial and residential settings. The system's high capacity ensures that even in the hottest months, indoor environments remain cool and comfortable, contributing to a pleasant and productive atmosphere.
This heat pump is also versatile enough for in ground heating and cooling applications. It can be used in conjunction with ground source systems to provide efficient temperature control for buildings that utilize geothermal energy. Its ability to handle both heating and cooling with ease makes it a valuable asset for properties with ground source heating and cooling systems.
As a heat pump to cool house, the 70℃ R417A 45KW unit offers excellent performance in residential cooling applications. Its high efficiency and capacity ensure that homes remain comfortable during the summer months, providing reliable relief from heat. The system's advanced features also contribute to energy savings, making it an economical choice for residential cooling.
Enhanced Vapor Injection (EVI) Technology: Provides superior efficiency and performance, even in extreme temperatures, ensuring consistent heating and cooling.
Ducted System Compatibility: Integrates seamlessly with existing ductwork, delivering even and effective climate control throughout the building.
Air Conditioning Excellence: Functions as an effective air conditioning unit, providing reliable and efficient cooling for commercial and residential applications.
Versatile Applications: Suitable for both in-ground heating and cooling systems, offering flexibility for various climate control needs.
High Capacity Output: With a 45KW capacity, this heat pump is capable of handling large heating and cooling loads, making it ideal for substantial spaces.
Energy Efficiency: Designed to maximize energy savings while delivering reliable performance, contributing to lower operational costs and reduced environmental impact.
Comfortable Climate Control: Ensures consistent indoor temperatures, preventing hot or cold spots and enhancing overall comfort.
Economical Choice: Offers an efficient and cost-effective solution for both heating and cooling, making it a smart investment for long-term climate control.
parameter
| BKFXFC-045UCII | |||
| Heating capacity (A7W65) | 45 kW | COP | 2.65 |
| Heating capacity (A15W65) | 50 kW | COP | 2.85 |
| Heating capacity (A-20W65) | 32.2 kW | COP | 2.06 |
| Compressor | HITACHI | ERP(35℃) | A +++ |
| Refrigerant Type | R417A | Max.Water Output Temp.(℃) | 70 |
| Power Supply | 400V 3N~ 50Hz | Max. Running Current (A) | 50 |
| Circulating Water Flow (m³/h) | 7.7 | Water Outlet Size | 2×DN65 |
| Water Side Pressure Loss(kPa) | ≤50 | Noise (dB(A)) | 65 |
| Dimension (W×D×H) | 2018×988×1896 mm | Packing Dimension (W×D×H) | 2110*1080*2100 mm |
| N.W.( kg) | 620 | G.W.( kg) | 650 |
| Note: A7W65 heating conditions: ambient dry bulb temperature 7°C, wet bulb temperature 6°C, hot water inlet/outlet temperature 60/65°C; A-15W65 heating condition: ambient dry bulb temperature -15°C, hot water outlet temperature 65°C. If the specification of the product changes due to improvement, the parameters on the nameplate shall prevail. | |||
Details

High Efficiency A+++ Energy Level
Targeting the European market, 3VF+ Series Air to Water Heat Pump is specially developed with the most cutting-edge heat
pump technology and modern design to meet stringent requirements for efficiency, stability and quietness. Not only does 3VF+
series use R32 Refrigerant and full DC Inverter EVI technology, but also be rated with A+++ energy label. With top energy
rating A+++ , the unit is currently most energy efficient and can greatly reduce energy bills for customers.

High Efficiency Full DC Inverter Compressor
Adopt DC inverter compressor and DC brushless fan motor, which can realize 20%-120% stepless capacity adjustment. During operation, the speed of the compressor and fan can be automatically and intelligently adjusted according to the actual load demand of the user, so as to reduce the energy consumption of the compressor and fan , so that the unit operates at the optimal level and achieves the energy saving purpose of on-demand output

Automatic defrost mode + anti-secondary long ice technology
The outdoor unit adopts outdoor temperature sensor and heat exchanger temperature sensor to perform variable-parameterdefrosting and accurately grasp the defrosting timing, which effectively solves the problem of "no defrosting when there is
frost, but defrosting without frost", and the amount of frost per unit time is significantly reduced. Only 1/3 of the normal defrostmode.At the same time, with the unique anti-secondary long-ice technology of AIROSD,
it can ensure that there is no frost at thebottom of the outdoor heat exchanger during heating in winter, and at the same time,
the ice water mixture left along the finscan be fully heated to a liquid state during defrosting. It is drained through the bottom drain hole to avoid poor heating effectcaused by the accumulation of frost at the bottom.